Double Float Buchholz Relay (DN25 - DN80)
Designed for oil-immersed power transformers. Features dual magnetic reed switches for independent alarm and trip outputs, IP67 enclosure protection, and calibrated surge flap mechanism.
Contact UsAn exhaustive technical specification manual and procurement directory for industrial power engineers, substation asset managers, and international EPC buyers. Manufactured by KROS Electric Co., Ltd. with 35+ years of precision electrical engineering expertise.
In high-voltage oil-immersed power transformers and distribution networks, the Buchholz Relay serves as the primary line of defense against internal electrical and thermal anomalies. Situated in the connecting pipework between the main transformer tank and the overhead conservator vessel, the Buchholz relay acts as a gas-actuated protective device designed to detect incipient faults—such as localized overheating, inter-turn short circuits, insulation breakdown, and partial discharge—long before catastrophic dielectric failure occurs.
However, a Buchholz relay cannot operate effectively in isolation. The overall reliability of transformer protection depends heavily on the quality, calibration, and structural integrity of Buchholz Relay Transformer Accessories. These specialized auxiliary components—ranging from remote gas collection devices, magnetic float assemblies, pneumatic testing cocks, and oil-surge flap valves to hermetically sealed microswitches—ensure accurate diagnostic readings, eliminate false tripping caused by mechanical vibrations, and facilitate safe ground-level testing without interrupting transformer operation.
A standard Buchholz protective loop manufactured by KROS Electric Co., Ltd. incorporates several high-precision auxiliary accessories engineered to survive harsh outdoor environments, extreme ambient temperature fluctuations (-40°C to +120°C oil temperature), and seismic forces:
Engineered under the direct leadership of our Founder & Chairman, Mr. I. Narayana Rao—who brings over 40 years of pioneering transformer design experience—our Buchholz relay accessories meet rigorous BIS (Bureau of Indian Standards) and international quality criteria, preventing costly unplanned outages across utility and industrial grids worldwide.
KROS Electric Co., Ltd. manufactures a wide array of standardized and customized transformer safety accessories designed for seamless integration with power transformers up to 10 MVA and beyond.
Designed for oil-immersed power transformers. Features dual magnetic reed switches for independent alarm and trip outputs, IP67 enclosure protection, and calibrated surge flap mechanism.
Contact Us
Eliminates working-at-height hazards. Includes stainless steel micro-bore tubing, dual isolation valves, and gas sampling vessel connection port for rapid substation DGA analysis.
Contact Us
Gold-flashed contact elements housed in vacuum-sealed glass tubes. Immune to transformer vibration, oil oxidation, and ambient humidity spikes up to 100% RH.
Contact Us
Brass and stainless steel test cocks engineered for high-pressure air injection testing and precise oil sampling from the upper relay dome structure.
Contact UsSelecting the appropriate Buchholz Relay Transformer Accessories requires precise matching with transformer capacity, pipe nominal diameter (DN), oil circulation speed, and system protection parameters. Below is the standardized engineering matrix provided by KROS Electric Co., Ltd. for global procurement planning:
| Parameter / Specification | DN25 (1 Inch) Accessories | DN50 (2 Inch) Accessories | DN80 (3 Inch) Accessories |
|---|---|---|---|
| Transformer Capacity Range | Up to 1,000 kVA (Distribution) | 1,000 kVA – 5,000 kVA (Power) | Above 5,000 kVA (High Voltage) |
| Pipe Inner Diameter (ID) | 25 mm | 50 mm | 80 mm |
| Gas Alarm Volume Sensitivity | 150 cm³ – 250 cm³ | 200 cm³ – 300 cm³ | 250 cm³ – 350 cm³ |
| Oil Surge Trip Velocity Range | 0.75 m/s – 1.50 m/s | 1.00 m/s – 2.00 m/s | 1.25 m/s – 3.00 m/s |
| Contact Type & Rating | 2x SPST / Reed Contacts (AC/DC 250V, 2A) | 2x SPDT / Changeover Contacts (AC/DC 250V, 2A) | 2x NO + 2x NC Heavy-Duty Contacts (250V, 5A) |
| Enclosure Protection Class | IP65 Weatherproof cast aluminum | IP67 Marine-grade anti-corrosive powder coated | IP68 Submersible / Tropicalized design |
| Gasket Material Compatibility | NBR (Nitrile), FKM (Viton) | Fluorosilicone / Ester oil compatible Viton | High-Temp Synthetic Ester Resistant Elastomers |
| Operating Temperature Range | -30°C to +105°C | -40°C to +115°C | -50°C to +130°C |
* Custom flanging (ANSI, DIN, BS, JIS), high-magnetic resistance shielding, and fiber-optic communication interfaces are available upon engineering request.
As power grids worldwide transition toward digital substations, renewable energy integration, and smart asset management, the demands placed on transformer protection accessories are rapidly evolving. Global B2B procurement managers and EPC contractors must consider the following emerging technological trends when specifying transformer safety components:
Traditional mechanical reed contacts are being augmented with digital gas accumulation sensors and continuous oil flow rate transmitters. Next-generation Buchholz relay accessories connect directly to SCADA systems via RS485 Modbus or IEC 61850 protocols, transmitting real-time data on gas buildup speed and localized temperature metrics for predictive maintenance analytics.
With the rapid expansion of solar, wind, and environmentally sensitive power installations, utilities are replacing mineral insulating oil with natural and synthetic ester fluids. Buchholz accessories must be fitted with specialized fluorosilicone and Viton-FKM sealing gaskets that resist chemical swelling and degradation when exposed to high-viscosity bio-oils.
Substation safety regulations increasingly restrict personnel from climbing onto live transformer covers for routine testing. Advanced remote gas collection units with automated optical sight chambers allow field technicians to inspect gas color, measure gas volume, and extract DGA samples at ground level safely.
Climate volatility has heightened demand for seismic-rated relay housings and anti-vibration microswitch mountings capable of withstanding heavy operational shocks, extreme UV radiation in desert solar plants, and coastal salt mist corrosion.
Selecting reliable protective accessories is a matter of critical substation security. A single failed microswitch or leaking gas sampling joint can cause unmonitored insulation breakdown, leading to multi-million-dollar transformer failures and extensive power outages. KROS Electric Co., Ltd. stands out as a world-class manufacturing partner backed by decades of proven field performance:
Established in 1990 by Mr. I. Narayana Rao, KROS Electric has grown from a specialized engineering firm into a global leader in transformer manufacturing and accessory design, leveraging over four decades of deep technical domain expertise.
Our state-of-the-art facility in Hyderabad operates under strict ISO quality management protocols. Our products hold Bureau of Indian Standards (BIS) certification (Licence No. CM/L-6300090908), ensuring total compliance with international electrical standards.
Every Buchholz relay and auxiliary fitting undergoes 100% factory routine testing, including pressure tightness tests, high-voltage dielectric contact isolation tests, gas response calibration, and helium leakage detection prior to dispatch.
Trusted by over 500+ satisfied clients across utilities, solar farms, railways, healthcare, and industrial heavy sectors. With over 20 MVA power capacity exported globally, we supply equipment built to withstand extreme international site conditions.
Clear technical answers to essential questions commonly asked by utility buyers, EPC contractors, and substation maintenance teams regarding Buchholz relay accessories.
Connect directly with senior transformer application engineers at KROS Electric Co., Ltd. We offer rapid customized design engineering, OEM matching, and global export shipping.